Gable Angle Punching:
Gable
Angle ON Module (----SGA-----) Gable
Angle (---VGA-----) Gable
Angle at Roof Extension Gable
Angle at Roof Height Change / Perpendicular Transition Note: The ---SGA----- is only on the lower
roof when the lower roof panel is Butlerib II. Holes in Gable Angle are automatically
located per condition. |
---SGA----- |
||||||
Length |
||||||
4'-0"
min, 20'-0" max |
||||||
1/4" gap
at eave and ridge. |
||||||
Gap between
SGA's = 1/2". |
||||||
Must attach
to 2 or more Roof Secondary Members. |
||||||
Locations of
brakes / gaps to be determined by Vision. |
||||||
Panel
Punching |
||||||
Only Panel Holes
that Line Up will be punched. Butlerib II
Punched (Only Roof Pitches = 0.25, 0.5, 1, 2, and 4:12) Shadowall
Punched (Only Roof Pitches = 0.25, 0.5, 1, and 2:12) All other
conditions will not have Panel Punching. |
||||||
Roof
Secondary Punching |
||||||
Additional
Holes at Corner Zones Secondary. |
||||||
Use the hole
location that is furthest upslope at Truss Purlins. |
||||||
Also used at
Roof Height Change transition. |
||||||
Roof
Extensions |
||||||
At the
Building Line - detail the Gable Angle using the same rules as above. Field
notch around roof secondary. |
||||||
At the End of
the Roof Extension, there is a Rake Channel, not a Gable Angle. |
||||||
Material |
||||||
|
G30 and G90
only. If other Primer Color is selected, then G30 is the default. |
|||||
If G90,
manufacturing is to substitute the material to a standard blank. Note:
Vision will generate a G30 SGA when Secondary Color is G90. To change the SGA to a SGA90 go to
Secondary Member Data/Warehouse screen and blank out the Color then go to the
Finish box and select Standard Primer now go back to color and select
Standard Color now you can change the part number from SGA to SGA90. |
||||||
CMR Rigid
Board Clip |
||||||
Punch 34 to
line up with Punch 35 at CMR Clip w/ 1 3/4" - 4" Rigid Board
Insulation. |
||||||
---VGA-----
(Variable) |
||||||
Used at
Skews. Panel
punching (punches 30 – 34) not available. |
||||||
Used at Special
Roof Secondary End Adjustments > 1/4" and < 3 1/4". |
||||||
KGA20 (No
Holes) |
||||||
Used at Bar
Joist. |
||||||
Used at
Partitions. |
||||||