Secondary - Gable Angle
(Revised: 09/22/20211)

Gable Angle Punching:

Gable Angle ON Module (----SGA-----)
9/16" x 7/8" Slot in Purlin

Gable Angle (---VGA-----)
9/16" x 7/8" Slot in Purlin
(Not automated)

Gable Angle at Roof Extension
(Field Drill Purlin)

 

Gable Angle at Roof Height Change / Perpendicular Transition

Note: The ---SGA----- is only on the lower roof when the lower roof panel is Butlerib II.
(Field Drill Low Purlin)

 

Holes in Gable Angle are automatically located per condition.

 

 

 

---SGA-----

Length

4'-0" min, 20'-0" max

1/4" gap at eave and ridge.

Gap between SGA's = 1/2".

Must attach to 2 or more Roof Secondary Members.

Locations of brakes / gaps to be determined by Vision.

Panel Punching

Only Panel Holes that Line Up will be punched.

Butlerib II Punched (Only Roof Pitches = 0.25, 0.5, 1, 2, and 4:12)

Shadowall Punched (Only Roof Pitches = 0.25, 0.5, 1, and 2:12)

All other conditions will not have Panel Punching.

Roof Secondary Punching

Additional Holes at Corner Zones Secondary.

Use the hole location that is furthest upslope at Truss Purlins.

Also used at Roof Height Change transition.

Roof Extensions

At the Building Line - detail the Gable Angle using the same rules as above. Field notch around roof secondary.

At the End of the Roof Extension, there is a Rake Channel, not a Gable Angle.

Material

               

G30 and G90 only. If other Primer Color is selected, then G30 is the default.

If G90, manufacturing is to substitute the material to a standard blank.

Note: Vision will generate a G30 SGA when Secondary Color is G90.  To change the SGA to a SGA90 go to Secondary Member Data/Warehouse screen and blank out the Color then go to the Finish box and select Standard Primer now go back to color and select Standard Color now you can change the part number from SGA to SGA90.

CMR Rigid Board Clip

Punch 34 to line up with Punch 35 at CMR Clip w/ 1 3/4" - 4" Rigid Board Insulation.

 

---VGA----- (Variable)

Used at Skews.

Panel punching (punches 30 – 34) not available.

Used at Special Roof Secondary End Adjustments > 1/4" and < 3 1/4".

KGA20 (No Holes)

Used at Bar Joist.

Used at Partitions.